Laserwelt investiert in neueste Technik!Der neue Tattoolaser "Trivantage" von Syneron/Candela ist...
Kein Aprilscherz!Was gut ist gehört einfach zusammen! Bereits während der AAD (American Academy of...
Wie oft haben Sie sich schon über minderqualifizierte Konkurrenten gewundert, die mit bombastischem...
Laserweltteam has won another University Hospital as new costumer. Prof. Dr. med. Dr. h.c. Thomas...
Frim now on also Prof. Giunta the new Chief of surgery departement of LMU University Munich owns a...
Hans Metelmann, Professor of the University Greifswald and Study Chairman DALM (Diploma in...
Laserwelt has won University Clinic Salzburg ENT as new High End Costumer. Prof. Rasp as Top Chief...
worldwide wellknown Univ.-Prof. Dr. Dr. med. Prof. h.c. (RC) Norbert Pallua and his teamDr. med....
University Hospital Leipzig - Oral and Maxillofacial Surgery is working with Canfield Vectra M3.
as new Canfield Vectra User. Prof. Paasch and Dr. Wagner are very happy to offer the new 3D Vectra...
Laserwelt hat keine Kosten und Mühen gescheut und unterstützt Dr. Klaus Hoffmann auf seiner...
The higher the frequency, the less the resistance of biological tissue to electromagnetic fields – up to the point where the cell membranes are capacitively coupled. This is exactly what happens with the 4 MHz produced by the CURIS® (both in the monopolar and the bipolar modes).
The electromagnetic fields are active in the tissue cells – not as is the case with conventional electrosurgical units, between the cells.
As a result energy is administered gently and in a highly focussed fashion. For example precise monopolar cuts are possible while lateral heat damage is kept to a minimum.
p3™ is active in all coagulation modes of the CURIS®. Radiofrequency energy is delivered in small packages of about 50 per second.
Due to the pulsed power output, there are very short breaks between the individual packages. The tissue has the time to absorb and distribute the energy and will generally be less traumatised. Highly-focussed, yet gentle coagulation with minimal thermal damage is possible. The p3™ process is, of course, AutoRF™ controlled.
The AutoRF™ function is the main control feature of the CURIS®. It responds to tissue impedance in all modes and controls and adjusts the power output according to tissue resistance.
The AutoRF™ function of the CURIS® will tailor the energy output (if need be even cut off or drive to the chosen maximum) in order to to ensure reproducible surgical results during cutting or coagulation.